Four RLL (relay ladder logic) CPUs provide a wide range of power and features while minimizing cost, providing up to 30.4 K memory, 16,384 I/O points, 230+ RLL instructions, and 16 PID loops
DL205 Flow Chart programmed CPUs (WinPLC System)DL205 Flow Chart programmed CPUs (WinPLC System)
The WinPLC is a revolutionary product that brings the best of the PC-based control and the programmable logic controller (PLC) worlds to a common platform.
DL205 Bases & Local I/O ExpansionDL205 Bases & Local I/O Expansion
Four Base sizes (3-slot, 4-slot, 6-slot and 9-slot) are available for local, local expansion, and remote I/O configurations, with choice of 110/230vAC or 12/24vDC power supply.
DL205 DC I/O modulesDL205 DC I/O modules
DC Inputs
8-16-32 point, 12-24 VDC, sink/source
DC Outputs
4-8-16-32 pt. 12-24 VDC, source and sink up to 4A per point.
DL205 AC I/O modulesDL205 AC I/O modules
AC Inputs
8-16 pt. 110 VAC, 8 pt. 220 VAC
AC Outputs
8-pt. 18-220 VAC, 12-pt. 18-110 VAC,
8-pt. 20-125 VAC, up to 1.5A per point.
DL205 AC/DC (Relay) I/O modulesDL205 AC/DC (Relay) I/O modules
AC/DC Relay Output 4-8-12 point up to 7A per point.
Combination I/O 4-pt. DC in, 4-pt. relay out
DL205 Analogue I/O modulesDL205 Analogue I/O modules
A wide range of analogue and temperature modules connect to almost any device including RTDs and thermocouples.
DL205 Serial Remote I/ODL205 Serial Remote I/O
A Remote I/O system consists of one master (D2-RMSM) and up to seven slave modules (D2-RSSS) using the RM-Net protocol, or up to 31 slaves using the SM-NET protocol.
DL205 Ethernet Remote I/ODL205 Ethernet Remote I/O
The Ethernet Remote Master H2-ERM(-F) connects 240, D2-250, 250-1, 260 and WinPLC systems to slave I/O over a high-speed Ethernet link.
DL205 Communications & NetworkingDL205 Communications & Networking
The DL205 PLC family offers many connectivity options, making it suitable for almost any communication intensive application via serial MODBUS RTU or Ethernet TCP/IP networks.
DL205 Speciality modulesDL205 Speciality modules
  • The H2-CTRIO counter/motion control module (100kHz) is the affordable, high-performance, high-feature solution for counting input and pulse output.
  • Triple-port BASIC Coprocessor
  • High-speed Counter I/O Module (5kHz)
  • Counter Interface Module
  • Input Simulator
DL205 Optional Program MemoryDL205 Optional Program Memory
  • D2-EE-1 - 8K EEPROM for use with D2-230, DL05 and DL06 CPUs or handheld programmer
  • D2-EE-2 - 32K EEPROM for use with D2-240 or handheld programmer
Programming software & cablesProgramming software & cables
The new DirectSOFT5 software package offers a host of advanced features for easier PLC programming.
  • Full-featured 32-bit Windows-certified programming for all DirectLOGIC PLCs
  • ALL NEW IBox instructions
  • FREE version allows a maximum of 100 words for programming, editing, and downloading
DL205 PLC ZipLinksDL205 PLC ZipLinks
ZIPLinks eliminate the tedious process of wiring programmable logic controller I/O to terminal blocks using half the space, at a fraction of the total cost of terminal blocks
  • ZIPLinks are available for all 8, 16 and 32-point discrete and analogue input and output modules (excluding RTD/THM)
DL205 Spare parts & AccessoriesDL205 Spare parts & Accessories
Everything needed to get and keep a DL205 system up and running.
  • Screws, fuses, connectors
  • Filler modules, modules covers
  • Batteries, cable kits
  • Converters, adapters
  • AutoCAD® Compatible Schematic Software

(4.16Mb)     (1.45Mb)      (24.6Mb)      (links)

DL205: Great Fit For On/Off Sequential Control

 

dl05_super_powerful.pdf (915kb)

Low prices on I/O
gives the DL205 a cost advantage on small and large I/O systems.
Great sequential instructions
- Drum instructions are an efficient way to program sequential operations and our drums are made super easy to program with point and click editing.
Practical built-in communications
now includes ASCII in and out. The D2-260 offers two built-in comm ports. Connect a text panel or touch panel to one port and a bar code reader or scale to the second port.
RLL and RLL+ programming
Our Relay Ladder Logic (RLL) incorporates intelligent modularized instructions (IBoxes) that perform simple to complex ladder logic. RLL +, or “stage” programming, has instructions to break the program into “stages” or states of a flow chart.
Expands from 8 I/O to 8,000 I/O
Four base sizes can be connected via local expansion I/O, serial remote I/O and Ethernet remote I/O to create a system as large as 8,192 I/O addressed by a single D2-260 CPU.
High-density modules
save space and money, and can be wired in seconds using ZIPLinks. ZIPLink products are a very low cost and fast way to wire using feedthrough, relay, fuse and LED terminals.

DL205: Great Fit for Applications with Analogue and PID Control

 

dl05_super_powerful.pdf (755kb)

Really low prices
Combine a 4-channel analogue input module with our DL05 PLC for low-cost analogue monitoring. Use the built-in PID loops and build a micro control system at an unbeatable price.
Low cost RTU system
for almost any remote dial-up application. Combine a DL05 AC- or DC-powered unit with our industrial telephone modem and avoid the high cost of an advanced Remote Telemetry System (RTU).
Practical connectivity
built-in with two RS-232 serial communication ports. Port 2 supports industry standard Modbus RTU protocol (master and slave at 38.4K baud).
Analogue option modules
The smallest and lowest priced in the industry. Seven 12-bit, and eight fast 16-bit high resolution models to choose from, including RTD and thermocouple.
Four PID loops
with auto tuning included at no additional charge. DirectSOFT programming software includes a loop tune screen with trending, and fill-in charts for alarms and ramp/soak profiles.
Low-cost process control
The small size and flexible features of the DL05 make for a great low-cost process control system. Connect a temperature sensor to an analogue input module. Then, control process loads like heater elements and/or mixers with DL05 discrete outputs using "time-proportioning" and the built-in PID.

DL205: Great Fit for Communication-Intensive Applications

 

dl05_super_powerful.pdf (704kb)

Really low prices
Combine a 4-channel analogue input module with our DL05 PLC for low-cost analogue monitoring. Use the built-in PID loops and build a micro control system at an unbeatable price.
Low cost RTU system
for almost any remote dial-up application. Combine a DL05 AC- or DC-powered unit with our industrial telephone modem and avoid the high cost of an advanced Remote Telemetry System (RTU).
Practical connectivity
built-in with two RS-232 serial communication ports. Port 2 supports industry standard Modbus RTU protocol (master and slave at 38.4K baud).
Analogue option modules
The smallest and lowest priced in the industry. Seven 12-bit, and eight fast 16-bit high resolution models to choose from, including RTD and thermocouple.
Four PID loops
with auto tuning included at no additional charge. DirectSOFT programming software includes a loop tune screen with trending, and fill-in charts for alarms and ramp/soak profiles.
Low-cost process control
The small size and flexible features of the DL05 make for a great low-cost process control system. Connect a temperature sensor to an analogue input module. Then, control process loads like heater elements and/or mixers with DL05 discrete outputs using "time-proportioning" and the built-in PID.

DL205: Great Fit for Simple Data Acquisition and Supervisory Control

 

dl05_super_powerful.pdf (705kb)

Really low prices
Combine a 4-channel analogue input module with our DL05 PLC for low-cost analogue monitoring. Use the built-in PID loops and build a micro control system at an unbeatable price.
Low cost RTU system
for almost any remote dial-up application. Combine a DL05 AC- or DC-powered unit with our industrial telephone modem and avoid the high cost of an advanced Remote Telemetry System (RTU).
Practical connectivity
built-in with two RS-232 serial communication ports. Port 2 supports industry standard Modbus RTU protocol (master and slave at 38.4K baud).
Analogue option modules
The smallest and lowest priced in the industry. Seven 12-bit, and eight fast 16-bit high resolution models to choose from, including RTD and thermocouple.
Four PID loops
with auto tuning included at no additional charge. DirectSOFT programming software includes a loop tune screen with trending, and fill-in charts for alarms and ramp/soak profiles.
Low-cost process control
The small size and flexible features of the DL05 make for a great low-cost process control system. Connect a temperature sensor to an analogue input module. Then, control process loads like heater elements and/or mixers with DL05 discrete outputs using "time-proportioning" and the built-in PID.

More Great Fits for the DL205

Counter/Pulse Applications

Stepper and Servo Control

dl05_super_powerful.pdf(708KB)

dl05_super_powerful.pdf (707KB)

Your first priority when designing a process control system should be safety. Please make sure that all of the automation components in your system will operate within the product’s environmental and operating specifications. Before you begin selecting products for your DL205 PLC system, be sure to evaluate all of your application needs and any future growth potential. .

STEP 1: Review the DL205 family of products:
The DL205 family offers a wide variety of products. Please review the product offerings, including:
  • CPUs
  • PLC programming tools (DirectSoft5 Programming Software or Handheld Programmer)
  • Bases (3, 4, 6 or 9-slot)
  • Local expansion modules
  • Discrete input modules (DC and AC input)
  • Discrete output modules (DC, AC and relay output)
  • Combination discrete modules
  • Analogue modules (Analogue input, analogue ouput, combination analogue in/out, temperature input)
  • Communications/networking modules (Ethernet or data communications modules)
  • Remote I/O modules (Ethernet or serial)
  • Specialty modules (Basic CoProcessor, Input Simulator, Counter I/O, Counter Interface)
  • CPU-slot slave controllers (Ethernet Base Controller, DeviceNET slave, Profibus slave, SDS slave)
  • Operator Interfaces (C-micro/Optimate text panels or C-more Touch panels and configuration software)
  • Connection systems (DINnector terminal blocks, ZIPLink connection systems and other accessories)
STEP 2: Select a CPU, PLC programming tool, and appropriate cables:
The DL205 PLC family offers four CPUs: the D2-260, D2-250-1, D2-240 and D2- 230. The WinPLC, a Windows® CE-based CPU, is also covered in this step. Please take the time to understand the features and specifications of each CPU model (i.e. built-in communications ports protocols, instructions, etc.). To program the DL205 CPUs, choose between the Windows-based DirectSOFT5 PLC programming software and PC cable or a handheld programmer. The WinPLC requires Entivity Studio or Think & Do Live for programming. CPU-slot slave base controllers are also introduced in this step.

STEP 3: Determine if additional communication ports are needed:
If your application requires more than the built-in CPU communications ports, then select the H2-ECOM Ethernet Communications Module or the D2-DCM Serial Communications Module. These modules add more ports for networking or connection to an HMI (Human Machine Interface), etc. The H2-SERIO serial communications module can be used with the WinPLC to add more communications ports.

STEP 4: Select the appropriate discrete, analogue and specialty I/O modules:
Since there are several different types of I/O and speciality modules available for the DL205 PLC system, it is important to review the module specifications in detail when selecting them for your process control system. The hardware specifications for the modules can be reviewed by clicking on the pdf datasheet link by each product.

STEP 5: Choose an I/O configuration method:
The DL205 PLC products offer several configurations of I/O. Choose among local I/O, local expansion I/O and remote I/O.
A DL205 system can be developed using a combination of the configuration arrangements. It is important to understand the octal addressing scheme and I/O module placement restrictions that are described in this step (See manual).

STEP 6: Check the power budget:
It is very important to verify that the selected CPU and I/O modules will operate within the base power budget. Tables are provided that list the power supplied and consumed by each DL205 PLC device. This step also describes base dimensions and mounting requirements. Calculate the power budget

STEP 7: Place your order!
Place your order either online, here at www.lamondeautomation.co.uk, by calling 01737-824600, or by faxing your order to 01737-821431.

Lamonde Automation
Project House, Morris Road, South Nutfield, Redhill, Surrey. RH1 5SA. UK
Call: 01737 824600
For Comments, Suggestions, Order Assistance and Sales...

© 2008 Lamonde Automation Ltd. All rights reserved.