 I/O module adapter for series 500CTI-2500-IADP I/O module adapter for series 500
The 2500-IADP is an I/O Adapter which allows the use of CTI 2500 Series I/O modules in Texas Instruments Series 500 I/O bases. It provides a transparent path for upgrading old Series 500 systems without the requirement to completely replace the system.

Failed 500 Series I/O modules can be replaced with CTI 2500 Series modules. Then, when your budget allows, you can plan a complete replacement of your system to CTI 2500 Series - without losing your investment in the replaced I/O modules!

Features:
  • Series 500 base format
  • Provides mechanical and electrical adaptation of CTI 2500 series I/O modules to operate in a Series 500 base
  • Compatible with all CTI 2500 Series discrete and analog
  • Allows replacement of failed Series 500 I/O modules with inexpensive and widely available CTI 2500 Series modules
  • Allows you to plan system upgrade according to your budget
  • Preserves your investment in replacement modules
Further details are available below:
data sheet
(5-10 working day delivery)
Quantity:  


 Power Supply module adapter for series 500CTI-2500-PADP Power Supply module adapter for series 500
The 2500-IADP is a Power Supply Adapter which allows the use of CTI 2500 Series power supplies in Texas Instruments Series 500 I/O bases. It provides a transparent path for upgrading old Series 500 systems without the requirement to completely replace the system. Failed 500 Series power supplies can be replaced with CTI 2500 Series modules. Then, when your budget allows, you can plan a complete replacement of your system to CTI 2500 Series - without losing your investment in the replaced modules!

Features:
  • Series 500 base format
  • Provides mechanical and electrical adaptation of CTI 2500 series power supplies to operate in a Series 500 base
  • Allows replacement of failed Series 500 power supplies with inexpensive and widely available CTI 2500 Series modules
  • Allows you to plan system upgrade according to your budget

data sheet
(5-10 working day delivery)
Quantity:  


 RBC adapter for series 500CTI-2500-RADP RBC adapter for series 500
The 2500-RADP is an RBC Adapter which allows the use of CTI 2500 Series™ RBCs in Texas Instruments Series 500 I/O bases. It provides a transparent path for upgrading old Series 500 systems without the requirement to completely replace the system.

Failed 500 Series RBCs can be replaced with CTI 2500 Series™ RBCs. Then, when your budget allows, you can plan a complete replacement of your system to CTI 2500 Series™ - without losing your investment in the replaced modules!

Features:
  • Series 500 base format
  • Provides mechanical and electrical adaptation of CTI 2500 Series™ RBCs to operate in a Series 500 base
  • Allows replacement of failed Series 500 RBCs with inexpensive and widely available CTI 2500 Series™ modules
  • Allows you to plan system upgrade according to your budget
  • Preserves your investment in replacement modules

data sheet
(5-10 working day delivery)
Quantity:  


 520/530/DBC Adapter for Series 500CTI-2500-R4500 520/530/DBC Adapter for Series 500
The 2500-R4500 is designed to replace various older style of Texas Instruments Programmable Controllers (520/530) and/or Distributed Base Controllers. The 520/530/ DBC units are commonly referred to as "oil pan" or "sump" units due to their boxy shape with ribbed fins. Note that the 520C/530C/530T programmable controllers (520C-1101/1102, 530C-1102/1104/1108/ 1112, 530T-1104/1112) are modular-type PLCs which attached to the I/O using the 500-5840 adapter base. These can be replaced using the R4500 adapter, or the 2500-RADP adapter sleeve.
Features
  • Connects to existing 500-5864/5828 I/O base (8-slot or 16-slot)
  • Use C100 for local-base only, or C200 for local and remote I/O
  • Download existing program
  • Re-use CTI products when remainder of Series 500 is changed out

data sheet
(5-10 working day delivery)
Quantity:  


 Analogue Wiring Adapter for Series 500CTI-2500-ADP1 Analogue Wiring Adapter for Series 500
The 2500-ADP1 is a wiring adapter which converts analogue field wiring from Series 500 base format to the 40-pin connector used on CTI 2500 Series™ analog I/O modules. This allows rapid upgrade of existing Series 500 systems to newer and more supportable 2500 Series™. It provides a transparent path for upgrading old Series 500 systems without the requirement to completely replace the system.

Features:
  • Converts 500-5037A 8ch Analog In connector to a CTI 2558 8ch Analog In 40F connector
  • Converts 500-5047A 8ch Analog Out connector to a CTI 2562 8ch Analog Out 40F connector
  • Allows easy replacement of failed Series 500 analog I/O modules with inexpensive and widely available CTI 2500 Series™ analog modules
  • Allows you to plan system upgrade according to your budget
  • Preserves your investment in replacement modules

data sheet
(5-10 working day delivery)
Quantity:  


 Discrete Wiring Adapter for Series 500CTI-2500-ADP2-DISC Discrete Wiring Adapter for Series 500
The 2500-ADP2-DISC is a wiring adapter which converts discrete I/O field wiring from the Series 500 base to the 40-pin connector used on CTI 2500 Series™ I/O modules. This allows rapid upgrade of existing Series 500 systems to newer and more supportable 2500 Series™
Features:
  • Adapter card to plug into Series 500 base (picks up I/O signals from base wiring)
  • 1 meter cable ready for termination to 2500- 40F connector on CTI I/O modules